A high-safety EO sterilization system for disposable healthcare products. The computer-controlled system ensures reliable sterilization without damaging materials.
| Availability: | |
|---|---|
| Quantity: | |
SMT-50
SMARTELL
High-Safety EO Gas Sterilization System for Disposable Healthcare Products

This EO sterilization system emphasizes operator and environmental safety with continuous EO concentration monitoring, sealed chamber design, and an automatic emergency ventilation system. It sterilizes syringes, masks, surgical kits, wound-care products, and catheter-based devices. The computerized control system allows programmable cycles and ensures accurate management of humidity, vacuum depth, and EO concentration. Reinforced stainless-steel construction and uniform airflow technology enhance gas distribution and improve sterilization consistency. The system offers long service life, strong stability, and full data recording for GMP documentation, making it ideal for healthcare product manufacturers with strict quality requirements.
![]()
| Structure | combined | Time control | 1min~99h |
| Specification | 1m3~35m3 | Power Supply | 380v 50HZ |
| Temperature control | 0~100°C | Power | 3~5Kw |
| Maximum error of the temperature control | <±3°C | Electric Power | 6~55Kw |
| Working pressure | -0.09~0.08Mpa | Working environment | Temperature5~40°C Humidity<80%RH |
| Working humidity | 30%~60% RH |




High-Safety EO Gas Sterilization System for Disposable Healthcare Products

This EO sterilization system emphasizes operator and environmental safety with continuous EO concentration monitoring, sealed chamber design, and an automatic emergency ventilation system. It sterilizes syringes, masks, surgical kits, wound-care products, and catheter-based devices. The computerized control system allows programmable cycles and ensures accurate management of humidity, vacuum depth, and EO concentration. Reinforced stainless-steel construction and uniform airflow technology enhance gas distribution and improve sterilization consistency. The system offers long service life, strong stability, and full data recording for GMP documentation, making it ideal for healthcare product manufacturers with strict quality requirements.
![]()
| Structure | combined | Time control | 1min~99h |
| Specification | 1m3~35m3 | Power Supply | 380v 50HZ |
| Temperature control | 0~100°C | Power | 3~5Kw |
| Maximum error of the temperature control | <±3°C | Electric Power | 6~55Kw |
| Working pressure | -0.09~0.08Mpa | Working environment | Temperature5~40°C Humidity<80%RH |
| Working humidity | 30%~60% RH |