SMT-5025
Smartell
(Stainless steel coating sterilizer cabinet)

| Structure | combined | Time control | 1min~99h |
| Specification | 1m3~35m3 | Power Supply | 380v/50HZ |
| Temperature control | 0~100°C | Power | 3~5Kw |
| Maximum error of the temperature control | <±3°C | Electric Power | 6~55Kw |
| Working pressure | -0.09~0.08Mpa | Working environment | Temperature5~40°C Humidity<80%RH |
| Working humidity | 30%~60% RH |
All parameters and dimensions are subject to change without prior notice.






(Stainless steel coating sterilizer cabinet)

| Structure | combined | Time control | 1min~99h |
| Specification | 1m3~35m3 | Power Supply | 380v/50HZ |
| Temperature control | 0~100°C | Power | 3~5Kw |
| Maximum error of the temperature control | <±3°C | Electric Power | 6~55Kw |
| Working pressure | -0.09~0.08Mpa | Working environment | Temperature5~40°C Humidity<80%RH |
| Working humidity | 30%~60% RH |
All parameters and dimensions are subject to change without prior notice.







Brief Introduction
Ethylene Oxide Sterilizer is the special equipment, sterilizing the things in the cabinet with ethylene oxide gas. It precedes low-temperature sterilization fumigation in the given terms of temperature, pressure and humidity.
The HMG-C series of ethylene oxide sterilizers are our new products of the third generation, which have absorbed advantages from both home and overseas. They are up to the EN1422 standards, can provide users the best technical support. The cylinder controls the automatic shift gate, the up-door seal inside of the silica tube make the gas tightness good.
The hexahedral hot-water circulatory makes water entering from many ways, which ensure the temperature in the cabinet more balanced.
We also manufacture a control system of the pretreatment cabinet type YC and the preheating room, to match the ethylene oxide sterilizer.
Sterilizer Cabinet Structure: composed by cabinet, circulating water heating system, vacuum devices, humidification devices, ethylene oxide gasification system, residual gas treatment plant, control system.
The Sterilizer Configuration (1)
The dedicated programmable computer control system can control temperature, pressure, humidity and time, do timing residual gas treatment, alert, print real-time data by micro-printer.
The Sterilizer Configuration (2)
The calculator control system controls the machine by institute laborers. It owns two modes of operation---manual and automatic, and friendly man-machine interface. It can control, watch over and alert the entire sterilization process automatically, including opening and closing the door; also can do real-time record about the sterilization parameters and the trends of temperature, pressure, humidity; can archive and print at any moment.


Brief Introduction
Ethylene Oxide Sterilizer is the special equipment, sterilizing the things in the cabinet with ethylene oxide gas. It precedes low-temperature sterilization fumigation in the given terms of temperature, pressure and humidity.
The HMG-C series of ethylene oxide sterilizers are our new products of the third generation, which have absorbed advantages from both home and overseas. They are up to the EN1422 standards, can provide users the best technical support. The cylinder controls the automatic shift gate, the up-door seal inside of the silica tube make the gas tightness good.
The hexahedral hot-water circulatory makes water entering from many ways, which ensure the temperature in the cabinet more balanced.
We also manufacture a control system of the pretreatment cabinet type YC and the preheating room, to match the ethylene oxide sterilizer.
Sterilizer Cabinet Structure: composed by cabinet, circulating water heating system, vacuum devices, humidification devices, ethylene oxide gasification system, residual gas treatment plant, control system.
The Sterilizer Configuration (1)
The dedicated programmable computer control system can control temperature, pressure, humidity and time, do timing residual gas treatment, alert, print real-time data by micro-printer.
The Sterilizer Configuration (2)
The calculator control system controls the machine by institute laborers. It owns two modes of operation---manual and automatic, and friendly man-machine interface. It can control, watch over and alert the entire sterilization process automatically, including opening and closing the door; also can do real-time record about the sterilization parameters and the trends of temperature, pressure, humidity; can archive and print at any moment.