SMT-5025
Smartell
(Stainless steel coating sterilizer cabinet)

| Structure | combined | Time control | 1min~99h |
| Specification | 1m3~35m3 | Power Supply | 380v/50HZ |
| Temperature control | 0~100°C | Power | 3~5Kw |
| Maximum error of the temperature control | <±3°C | Electric Power | 6~55Kw |
| Working pressure | -0.09~0.08Mpa | Working environment | Temperature5~40°C Humidity<80%RH |
| Working humidity | 30%~60% RH |
All parameters and dimensions are subject to change without prior notice.






(Stainless steel coating sterilizer cabinet)

| Structure | combined | Time control | 1min~99h |
| Specification | 1m3~35m3 | Power Supply | 380v/50HZ |
| Temperature control | 0~100°C | Power | 3~5Kw |
| Maximum error of the temperature control | <±3°C | Electric Power | 6~55Kw |
| Working pressure | -0.09~0.08Mpa | Working environment | Temperature5~40°C Humidity<80%RH |
| Working humidity | 30%~60% RH |
All parameters and dimensions are subject to change without prior notice.







Humidification Devices: Moisture is essential for the effectiveness of the ETO sterilization process. The humidification system introduces controlled amounts of water vapor into the chamber to achieve the correct humidity level, which improves the ability of ethylene oxide to penetrate packaging and sterilize the medical devices.
Ethylene Oxide Gasification System: This system is responsible for introducing ethylene oxide gas into the chamber at the correct concentration. The gasification system ensures that the ETO gas is uniformly distributed throughout the sterilization chamber, allowing it to penetrate all components of the medical devices being sterilized.
Residual Gas Treatment Plant: After the sterilization process is complete, any residual ethylene oxide gas inside the chamber must be safely removed. The residual gas treatment plant neutralizes and eliminates any leftover ETO gas to ensure that it does not pose a risk to the operator or contaminate the products. This treatment is critical for safety, as ethylene oxide is a toxic and potentially carcinogenic substance.
Control System: Modern ETO sterilization machines are equipped with a control system that automates and monitors the entire sterilization process. The system controls key parameters such as temperature, vacuum, humidity, and gas concentration. It also includes safety features like emergency shutdown mechanisms in case of malfunction or excessive gas concentrations.


Humidification Devices: Moisture is essential for the effectiveness of the ETO sterilization process. The humidification system introduces controlled amounts of water vapor into the chamber to achieve the correct humidity level, which improves the ability of ethylene oxide to penetrate packaging and sterilize the medical devices.
Ethylene Oxide Gasification System: This system is responsible for introducing ethylene oxide gas into the chamber at the correct concentration. The gasification system ensures that the ETO gas is uniformly distributed throughout the sterilization chamber, allowing it to penetrate all components of the medical devices being sterilized.
Residual Gas Treatment Plant: After the sterilization process is complete, any residual ethylene oxide gas inside the chamber must be safely removed. The residual gas treatment plant neutralizes and eliminates any leftover ETO gas to ensure that it does not pose a risk to the operator or contaminate the products. This treatment is critical for safety, as ethylene oxide is a toxic and potentially carcinogenic substance.
Control System: Modern ETO sterilization machines are equipped with a control system that automates and monitors the entire sterilization process. The system controls key parameters such as temperature, vacuum, humidity, and gas concentration. It also includes safety features like emergency shutdown mechanisms in case of malfunction or excessive gas concentrations.